WroclawSingle and double column aluminum alloy lifting platformThe development trend of the logistics industry

938HP166090698   ·  2024-05-04 00:40:24   ·   Machinery and industry equipment

Measurement of elevator and escalator shafts (III)The front room of the fire elevator is equipped with indoor fire hydrants.Wroclaw,Elevators are used to transport firefighters, passengers, and fire-fighting equipment in the event of a fire. They are used to transport frozen goods in large cold storage or refrigeration workshops. However, villa household elevators, household elevator manufacturers, and small household elevators have stable, safe, reliable, and maintenance free performance, and their technical level has reached the domestic level, the length of the upper and lower platforms of the escalator can be increased to meet the actual dimensions of civil engineering. One platform can be extended on one side, or both platforms can be extended simultaneously. The total extension of the upper and lower platforms should generally not exceed mm. When lengthening the platform, attention should be paid to the length of the pit or the opening of the floor slab, which should also be lengthened at the same time. After the escalator is extended, the force on the upper and lower support points will also increase. If the edge distance of the beam increases too long, support needs to be added in the middle of the escalator truss. In addition, changing the angle of the escalator from degrees to degrees can also make the beam edge distance longer.Arad, its safety cannot be guaranteed. If the elevator needs to be refueled without refueling, it will cause wear and tear on the mechanical components of the elevator, greatly shortening its service life and preventing normal use of the elevator.  “& rdquo; Elevator shaft: The design conditions are provided by the user to the architectural design department. The architectural design department analyzes whether the on-site pit depth, top floor height,WroclawHome villa sightseeing elevator, reaction force, etc. can meet the installation requirements of the elevator, as well as which building structures are needed (such as smashing stairs or floors), and develops a renovation construction plan. If it is indeed necessary to change the elevator structure due to civil engineering conditions (such as car size, door opening width, etc.), then consider the non-standard design of the elevator.


WroclawSingle and double column aluminum alloy lifting platformThe development trend of the logistics industry



The shaft for updating the old elevator: The measurement of the shaft for the old elevator is the same as the shaft that has just been constructed. When the old elevator is not yet in use,WroclawLarge hydraulic turnover machine, try to obtain relevant data outside the shaft, such as the size of the machine room floor height, and net size of the door opening. There are two situations when the old elevator is not yet in use: a. When the old elevator can start: in this case, the elevator technician must cooperate in measuring the shaft! And be sure to pay attention to safety! The elevator technician opens the hall door on the first floor and initiates maintenance operations to drive the car above the second floor. The measurement personnel open the floor door on the first floor to measure the pit data paying attention to recording the pit size and the wall structure of the first floor, such as whether the hall door is centered, whether there are brackets whether there are special structures on the shaft wall, the spacing between ring beams, and the position of embedded parts. Then, the measuring personnel and elevator technicians take the elevator to the top floor. After measuring the machine room, the measuring personnel, with the cooperation of the technicians, go up to the car roof and start the elevator at a maintenance speed. When the car roof is slightly lower than the sill of the second floor hall door, the parking lot stops. During this process, the measuring personnel observe and measure the full travel of the shaft from the top floor, mainly the height of the floor, while recording the measurement (safety must be paid attention to, and special attention should be paid to moving parts such as counterweights and wire ropes).The elevator stops on the first floor and the door does not move: the fire emergency landing function of the elevator is triggered by smoke or thermal sensors inside the building.Please note that there should be a space of over mm left on both sides of the escalator, and when arranged in parallel, there is no restriction between the two escalators.Word of mouth recommendation,Multiple elevator shafts can be connected and an - # I-beam can be fixed at a certain height between each adjacent elevator shaft,WroclawSide tipping hydraulic unloading and tipping machine, with the same position as the ring beam. The pit must be equipped with an isolation net that is mm above the ground level.The call button on each floor is no longer working, and the call is cut off.Cleaning and cleaning of elevator car guide shoes. As is well known, the guide shoe runs on the guide rail and there is an oil cup on the guide shoe. To ensure that the elevator does not make any noise during operation, it is necessary to regularly refuel the oil cup and clean the guide shoe, and the cabin should be cleaned thoroughly.


WroclawSingle and double column aluminum alloy lifting platformThe development trend of the logistics industry



For escalators that require intermediate support, it is necessary to determine whether the site has the conditions for adding support, the height and load size of the equipment and support platform, and other parameters.Welcome calls ,Please note that there should be a space of over mm left on both sides of the escalator, and when arranged in parallel, there is no restriction between the two escalators.When encountering abnormal elevator operation, you can call the repair hotline to consult with the maintenance personnel or inform the service center to handle it. Do not take unauthorized measures to avoid causing greater harm to the elevator or even causing casualties.Machine room power supply: The power supply should be three-phase V, HZ, and the lighting power supply should be single-phase V, HZ. The incoming line should be connected to the vicinity of the machine room entrance and equipped with an incoming socket. Specializing in product and renewable resource business, including: home elevator manufacturersWroclaw,The front room of the fire elevator is equipped with indoor fire hydrants.Tower style residential buildings above; Residential units and corridors with twelve or more floors; Other Class II public buildings with a building height exceeding meters; High rise buildings with elevators exceeding meters in height; The functional fire elevator has a front room. The area of the independent fire elevator front room is: the front room area of the residential building is greater than square meters; The front room area of public buildings and high-rise factory (warehouse) buildings is greater than square meters. When the front room of the fire elevator is shared with the smoke proof staircase, its area is: the area of the shared front room in residential buildings is greater than square meters, and the area of the shared front room in public buildings and high-rise factory (warehouse) buildings is greater than square meters.Please note that there should be a space of over mm left on both sides of the escalator, and when arranged in parallel, there is no restriction between the two escalators.


3 Replies   |  until 2024-05-04 00:40:24 | 61 Views

Deyitang Dafang Co., Ltd. 2024-05-04 08:01:57 support  0 | be opposed to  0

The logistics of WroclawSingle and double column aluminum alloy lifting platform is a bit slow. Overall it's good, I hope I have a chance to cooperate next time

Architectural Engineering Consulting 2024-05-04 10:01:31 support  0 | be opposed to  0

Feels of value for money, service attitude is very good, WroclawSingle and double column aluminum alloy lifting platform workmanship is very good, nothing fussy, all five points

Shelves 2024-05-04 09:05:03 support  0 | be opposed to  0

WroclawSingle and double column aluminum alloy lifting platformYes, give you a good comment
Log inContent can only be published later