Connect the refrigeration system. Wires and copper pipes shall be used to connect the refrigeration unit, and corresponding thermal insulation and protection measures shall be taken.A large number of personnel are not allowed to select goods in the warehouse. Close the warehouse door in time. When the warehouse door is opened, pay attention to whether the air curtain is opened or the door curtain is placed properly. Turn off the lights when leaving the warehouse.Turialba,After evacuation, fill the refrigerant into the liquid storage to % of the standard filling volume & mdash; % by weight, then run the compressor and add gas from low pressure to sufficient volume.Moreover, polyurethane does not produce harmful gas at high temperature.Cerete,The insulation board of the cold storage adopts polyurethane double-sided color steel plate. The main effect of this cold storage insulation board is good sealing performance, insulation effect and moisture-proof effect, so as to ensure the refrigeration effect of the cold storage. The electric cold storage door is adopted for the cold storage door, so as to avoid the loss of refrigeration capacity of the cold storage.During the production of cold storage, the cold storage will produce fixed length, width and thickness according to the needs of various cold storage projects. Generally, cm thick cold storage plates are selected for high and medium temperature cold storage. The requirements for cold storage engineering plates of low-temperature storage and quick-frozen storage will be higher. Professional cold storage installation, installation, construction, fruit fresh-keeping cold storage and medical cold storage ensure the quality, Guarantee service. Guarantee quality. Your satisfaction is our pursuit! Welcome to inquire. In this case, use cm or cm thick library board. When you budget the cold storage project, you can make a reservation according to the specific conditions of your cold storage temperature. If you don't make a reservation for the cold storage plate, you should pay attention to the density of the cold storage plate and the thickness of the steel plate when purchasing the cold storage plate. According to regulations, the foaming density of cold storage is per cubic meterFault phenomenon: fan motor overload, fan deformation; Fan motor fault; Fan motor thermal relay fault (aging); Loose wiring; Cooler blocked; Large exhaust resistance. Cold storage fault phenomenon: dryer does not operate compressor line is disconnected, fuse is blown,TurialbaCold storage of professional installation company, thermal relay acts, compressor is locked, line is falsely connected or loose fault phenomenon: it stops in a short time after drying, ambient temperature is too high, condenser is blocked
First use a hammer to pad the wood on the polyurethane warehouse board between the two warehouse boards, so as to make the boards closely close to each other. Two sets of connecting pieces shall be wedged between the wall panel and the wall panel, and the two sets of connecting pieces shall be fixed on the upper, outer and lower sides of the gap between the wall panel and the wall panel respectively. The lower connecting piece shall be as close as possible to the lower side, so that the post cast concrete can cover the connecting piece. After the gap between the plate and the plate ground is wedged with a connector it shall be about mm wide. If it does not meet the requirements, trim the plate edge, and then reinstall it to make the plate joint meet the requirements. When fixing the adapter, pay attention to fix the two parts of the adapter on the edges of the convex and concave library plates respectively, and fix them with rivets. The spacing of the adapter should be able to tension the two library plates. When wedging the wedge iron, the hammer shall be perpendicular to the wedge iron to prevent damaging the warehouse plate. The ground wedge iron at the upper and lower parts shall be wedged at the same time, and the wedge iron shall be fixed with rivets.The high pressure gauge shall be installed at the opening of the liquid storage tank valve.Preparation, prepare the project planning of cold storage, and prepare the construction site and construction materials. All kinds of materials for cold storage construction are customized according to the needs of customers. Sort out the construction site that meets the requirements, transport all installation materials to the construction site, check the material quality and model, and start the installation of cold storage after confirmation.demand,If there is more air or refrigerant oil in the evaporator,TurialbaPrice and installation of cold storage project, the heat transfer effect will be reduced: once more refrigerant oil is attached to the inner surface of the evaporator heat transfer tube, the heat transfer coefficient will be reduced. Similarly, if there is more air in the heat transfer tube, the heat exchange area of the evaporator will be reduced, the heat transfer efficiency will be significantly reduced, and the decline rate of warehouse temperature will be slowed down.Whether the parameters of refrigeration equipment are consistent. When the cold storage leaves the factory, the temperature and temperature difference parameters of the cold storage shall be customized according to the user's requirements. After understanding the technical parameters of the cold storage, set the parameters on the refrigerator. During use, the air humidity is high and the defrosting interval is long. The common cold storage boards of cold storage include mm, mm,TurialbaDrug preservation warehouse, mm, mm and mm polyurethane thermal insulation boards, color steel tiles, stainless steel plates, salt thick steel plates, embossed aluminum plates, polyurethane spraying, more general color steel tiles are produced and processed into hidden grooves, which have light weight, high compressive strength, good fire resistance, corrosion resistance and aging resistance, The cold storage board is simple and convenient to assemble, and is a wide range of raw materials selected for the heat insulation and heat preservation of the cold storage. The cost of stainless steel plate and salt plate increases and it is also easy to deform and damage the appearance.During the use of the goods yard medical cold storage project, the stored goods must be in strict accordance with the relevant regulations. The goods should have a certain distance from the ground and wall of the cold storage. When stacking, the distance between the goods and the goods must be cm. At the same time, the distance between the goods and the cold fan should also be cm. No goods can be stored within this range, This is also an important content in the use of medical cold storage engineering.
Relative humidity maintenance of quick-frozen warehouse: humidification of quick-frozen warehouse is very important, from centrifugal humidification to high-pressure micro fog humidification, gas-water mixed humidification, to the current ultrasonic humidifier. The utility model has the advantages of small particles, uniform humidification, no freezing and blocking, and no dirty blocking. The air conditioning humidifier we produce is specially designed for all kinds of vegetable and fruit quick freezing warehouses, which is essentially different from other humidifiers in the market: fully closed circulation, that is, take the gas in the warehouse, return to the warehouse through the humidifier and isolate it from the outside air.Credit guarantee,During the cold storage commissioning, special personnel shall be assigned to ensure that the surface of the cold storage plate shall reflect evenly without condensation and cold running; Sealing conditions of joints and holes; Whether the warehouse door and delivery port are not tightly sealed, and timely deal with the problems of insulation and seal failure such as degumming and air leakage.After the welding of the whole system, the air tightness test shall be carried out, and the high-pressure end shall be filled with mp nitrogen. Nitrogen charging MP at low pressure end. During pressurization, and carefully inspect all welded junctions, flanges and valves, so as to keep the pressure from falling off after the completion of simplicity.No matter whether the food cold storage or quick-frozen storage is in use it is inevitable that there will be various small faults. Don't be nervous when there are problems. You can find or eliminate problems according to the knowledge taught today.Turialba,At ordinary times, users should check the sealing degree of the gap of the cold storage, the Perpendicularity Error of wall plate shall be corrected while the top storehouse plate is installed. The length of the top warehouse plate shall be mm shorter than the surface of the wall plate. After the installation of the top warehouse plate, the mm gap shall be marked with foaming material to ensure the sealing performance of the warehouse body.Whether there is dirt on the condenser and poor heat dissipation will lead to too high condensation pressure of the refrigerator. In order to protect the compressor, the machine stops running under the action of the pressure controller. When the heat dissipation is good, press the black reset button on the pressure controller, and the machine can automatically resume operation.