In the low temperature environment especially in the periodic freezing and thawing cycle, the building structure is also vulnerable to. Therefore, the building materials of the cold storage and the structure of each part of the cold storage should have sufficient frost resistance.What should be considered in building a cold storage? In these aspects, meets the needs of refrigeration technology,KomapaInstallation price of vegetable cold storage, convenient production,However, due to high labor intensity and incomplete defrosting, it has limitations.The lights in the warehouse are not on. Please check whether the switch fails and whether the bulb is damaged. Cut off the power supply when installing the lampshade, and pay attention to the waterproof of the lamp.Katima Mulilo,Large space rate of quick-frozen warehouse: for quick-frozen warehouses of the same size, reasonable design schemes store more goods than unreasonable ones. For the fixed size quick freezing warehouse how to design it to maximize its space rate is often an important problem considered by our designers. In the design scheme of Lukang medical quick-frozen warehouse, we reasonably designed to expand the original storage capacity of boxes to boxes, which increases the space a lot.However, long-term continuous operation will inevitably lead to equipment aging, so reasonable maintenance is particularly important.According to the size and nature of the cold storage area and in combination with local regulations, the construction form of food cold storage warehouse is to determine the plane layout based on the site, whether it is a single-layer or double-layer warehouse and the structure is the selection of steel structure or reinforcement solidification. Cold storage capacity, production process, refrigeration, product stacking, temperature, etc. are used to determine the size and location of the cold storage room, so that it can become a whole.


KomapaInstallation of refrigeration equipment in cold storageRange



First, use a hammer to pad the wood on the polyurethane warehouse board between the two warehouse boards, so as to make the boards closely close to each other. Two sets of connecting pieces shall be wedged between the wall panel and the wall panel, and the two sets of connecting pieces shall be fixed on the upper, outer and lower sides of the gap between the wall panel and the wall panel respectively. The lower connecting piece shall be as close as possible to the lower side, so that the post cast concrete can cover the connecting piece. After the gap between the plate and the plate ground is wedged with a connector, it shall be about mm wide. If it does not meet the requirements, remove the plate, trim the plate edge, and then reinstall it to make the plate joint meet the requirements. When fixing the adapter, and fix them with rivets. The spacing of the adapter should be able to tension the two library plates. When wedging the wedge iron the hammer shall be perpendicular to the wedge iron to prevent damaging the warehouse plate. The ground wedge iron at the upper and lower parts shall be wedged at the same time, and the wedge iron shall be fixed with rivets.Building plan and other relevant data of cold storage construction project.The combined cold storage door starts frequently or does not start for a long time,KomapaCold storage installation company, or does not stop for a long time, or stops before the storage temperature reaches.Home page recommendation,Requirements for the cold storage time of the device: the cold storage of the refrigeration system using ammonia as refrigerant shall be supported in the place with low population density around.In the process of realizing your dream, you must remove all the influences. It is very important to recognize that when these beautiful refrigerators are built in the villa room, the collection pit (pool) for flushing (thawing) and drainage should adopt the Countermeasures of avoiding freezing and cleaning and avoiding backflow of water.Initial stage of cold storage equipment


KomapaInstallation of refrigeration equipment in cold storageRange



The water tank is designed to be separated from the machine body and is double-layer. It will not drip due to condensation caused by internal and external temperature difference. It can be interlocked with the refrigeration system, that is, it will not be humidified during refrigeration to prevent serious frosting of the fan.Excellent service,Immediate cooling is to install the condenser of the cold storage in the box or building of the cooling equipment, use the volatilization of the refrigerant to immediately cool the air in the air, and use the cold air to cool the objects that need to be cooled. This kind of refrigeration is characterized by faster cooling speed, small heat conduction temperature difference and simple system software, so it is widely used.Once there are impurities in the controlled atmosphere storage system, which will seriously affect the refrigeration capacity of the controlled atmosphere storage.The assembled cold storage body often adopts double-sided color steel plate of polyurethane thermal insulation material, which has excellent thermal insulation performance, storage and circulation effect and reduces operation energy consumption. Of course, more important is the choice of refrigeration system. For example, at present,KomapaCold storage installation price, the refrigeration system of fluorine refrigerant is still the mainstream, but when selecting the type and power of cooling equipment, it is necessary to calculate the data for the installation of cold storage, and then make a high-quality choice.Komapa,For the ground insulation of large cold storage, we can that the ground insulation of medium-sized cold storage is more complex than that of small cold storage, and the ground insulation operation of large cold storage with larger warehouse area will be more complex. The common operations are as follows: first lay the ventilation pipe to prevent the ground from freezing drum cracking, then lay the XPS extruded plate (staggered laying is required when laying the extruded plate), then lay the moisture-proof and vapor barrier on the upper and lower sides of the extruded plate, then pour the reinforced concrete (generally at least cm thick), and then make the emery floor or epoxy floor according to the requirements. Among them, the XPS extruded plate is also laid according to the warehouse temperature. For example, the XPS extruded plate with thickness of ~ mm needs to be laid in the general low-temperature cold storage, while the XPS extruded plate with thickness of ~ mm can be laid in the high-temperature cold storage.Generally speaking, the construction of cold storage is to ensure the quality of buildings with its strict heat insulation, sealing, firmness and frost resistance.The products stored in the medical cold storage project must be managed by color code, so as to avoid the problem of purchase errors. In the process of handling, it is also necessary to strictly follow the instructions.

2 Replies   |  until 2022-12-28 11:17:32 | 188 Views

FRP cooling tower 2022-12-28 13:01:09 support  0 | be opposed to  0

Since the last time I bought your KomapaInstallation of refrigeration equipment in cold storage, this new model has indeed met the standard and is very good, giving you a good comment.

denitrification 2022-12-28 12:01:10 support  0 | be opposed to  0

I really like it, I am very supportive, the quality is very good, exactly the same as described in KomapaInstallation of refrigeration equipment in cold storage, I am very satisfied, I really like it, completely exceed expectations, the delivery speed is very fast, the packaging is very careful and strict, and the logistics company services The attitude is very good, the delivery speed is very fast, and I am very satisfied with a shopping.
Log inContent can only be published later