AachenPrice and installation of cold storage projectPrecautions for use

632HP195506591   ·  2024-04-24 04:39:58   ·   energy

Refrigeration system: refrigeration system is the core part of cold storage design. It is the key to determine the economy environmental protection and performance of cold storage.We must often use insulation board in our life. It's just the structure of the refrigerator, but the refrigerator, as a in the home, still has some use environment. In the market or marine transportation, the environment of cold storage insulation board is not so optimistic. Professional cold storage installation, cold storage installation, fruit preservation cold storage, medical cold storage quality assurance. During the preferential activities, new and old customers are welcome to consult. The environmental differences inside and outside the cold storage insulation board are very large, because a large number of items need to be insulated, so the temperature in the cold storage is strict. In such cases, the cold storage insulation board will have relevant problems, Let's understand that the water vapor pressure outside the plate warehouse of the lower cold storage is higher than that inside the warehouse, and the penetration of the envelope is carried out from outside to inside all year round. R gas in polyurethane is replaced by air and water vapor to damp polyurethane. Over time, moisture becomes more and more serious, and even water vapor condensation occurs, resulting in low thermal conductivity and reduced thermal resistance. In order to avoid and delay polyurethane moisture and prolong the service life of the insulation layer, it is effective to seal the hot side of the insulation layer, that is, to form a vapor barrier layer.Aachen,The selection of refrigeration unit is carried out in the refrigeration equipment of cold storage. According to the heat consumption of production scale and considering the necessary conditions of main refrigeration parameters, the number and total number of refrigeration units and cold storage mechanical equipment are equipped.No matter whether the food cold storage or quick-frozen storage is in use, it is inevitable that there will be various small faults. Don't be nervous when there are problems. You can find or eliminate problems according to the knowledge taught today.Santo-Domingo. Maintenance of food cold storage. In a position convenient for operation outside the door of the refrigerator room, a main switch for cutting off the power supply of the refrigeration compressor shall be set. This switch shall be able to stop the operation of the refrigeration compressor, and relevant signs shall be set. If the mechanical panel is set in the main room, install and arrange the construction electrical equipment, moisture-proof, anti-collision anti binding and other safety protection.Installation of cold storage, construction of cold storage, fruit preservation cold storage and medical cold storage have stable, safe, reliable and maintenance free performance. The technical level has reached the domestic level and the advanced level of similar international products. If there is a large amount of ice and water, and it must not be knocked during cleaning, so as not to damage the ground and affect the service life of the cold storage.


AachenPrice and installation of cold storage projectPrecautions for use



Another reason is that there are many refrigerants in the system. In this case, find the leakage point first, focus on the connection of each pipeline and valve, repair the found part, and then fill in sufficient refrigerant.The type of cold storage to be built in the cold storage type shall be determined according to the type of circulating goods. For example, a cold storage that only circulates vegetables can only establish a fresh-keeping cold storage. If there are many kinds of circulating commodities and large differences in storage temperatures, a cold storage of refrigeration + freezing will be established. As for the size of the cold storage, quantity, frequency, cycle, whether to use shelves for stacking, etc. For example, for fruits and vegetables packed in cartons, refer to the storage capacity of -kg per cubic meter, andFrequently observe the operation state of the heart compressor of the cold storage equipment and its exhaust temperature. During the season change operation, pay special attention to the operation state of the system and adjust the liquid supply and condensation temperature of the system in time.Where is good,The polyurethane insulation board used in the construction of cold storage shall be integral and continuous,AachenCold storage installation discipline, and there shall be no joint in the middle. The junction of polyurethane insulation board,AachenConstant temperature medical cold storage, top plate and ground shall be made into fillet arc for transition, which can well meet the health needs.The structure of contemporary cold storage is in the development trend of prefabricated building cold storage. It is made into prefabricated components of cold storage including steam barrier and heat insulation plate to ensure on-site assembly. Its advantage is that the project construction is convenient, rapid and movable, but the project cost is relatively high.With the rapid development of modern commerce, the original cold storage for the purpose of product storage can no longer meet the rapid, accurate and small batch circulation needs of modern commodities. Therefore, the logistics center cold storage cold chain for the purpose of product distribution came into being and developed rapidly, playing a more and more important role in the commodity circulation chain. What are the characteristics of the rapid development of cold storage construction?


AachenPrice and installation of cold storage projectPrecautions for use



No matter whether the food cold storage or quick-frozen storage is in use, it is inevitable that there will be various small faults. Don't be nervous when there are problems. You can find or eliminate problems according to the knowledge taught today.Safety production,With the increasing use of cold storage, cold storage board, as an important structure of cold storage, is also increasing. Because cold storage is different from other ordinary cold storage, it is important to the installation environment and temperature. Therefore, some small problems may be ignored during installation. According to the following understanding.Replace the refrigeration oil. After years of service, the refrigeration oil inside the compressor shall be replaced. The oil stain, copper filings, iron filings and impurities caused by secondary wear are mixed in the refrigeration system, which thickens the refrigeration oil, deteriorates the fluidity and performance, reduces the effect takes a long time, increases the burden of the compressor, and the current will be higher than that of the new machine This is a bad phenomenon. Replace the refrigerant oil regularly and timely to maintain the good performance of the system, so as to ensure the long-term use of the equipment.Anti odor floor drain shall be set on the pavement of refrigeration room and refrigeration unit room, and the height width ratio of floor drain water seal shall not be less than mm. The elevator shaft, electronic pit and other places convenient for drainage shall be provided with drainage and equipment to avoid backflow of water.Aachen,Stretch perlite: stretch perlite is a kind of granular material with porous layout. The gap in it blocks out the heat. Professional cold storage installation, cold storage installation, cold storage construction, fruit fresh-keeping cold storage,AachenMedical cold storage temperature, strict testing, quality assurance. Preferential activities are in progress. Welcome to consult. It has a good heat insulation effect. Then, the water vapor in the cold storage is easy to condense, and the water absorption of extensional perlite is particularly strong. If it absorbs a lot of water, its nature will be greatly reduced. Therefore, it is necessary to be careful to select extensional perlite as cold storage.It is required to set up a special tally room (area), and the temperature of the tally area is usually controlled at ~ + ℃.For water-cooled units, the turbidity of cooling water shall be frequently, the cooling water shall be replaced frequently, and whether the running, emitting, dripping, leakage and other conditions of the water supply system exist.

3 Replies   |  until 2024-04-24 04:39:58 | 15 Views

pipe box 2024-04-24 13:40:59 support  0 | be opposed to  0

Now the business is not easy to do, can you give more discounts?

metal fasteners 2024-04-24 12:08:45 support  0 | be opposed to  0

It's worthy of praise, really good, AachenPrice and installation of cold storage project I like it very much.

Except for floor steel 2024-04-24 12:16:55 support  0 | be opposed to  0

I bought a lot of you AachenPrice and installation of cold storage project and I am very satisfied. Very good seller, I will come often.
Log inContent can only be published later