VeracruzFruit and vegetable cold storage installation companyCharacteristics and common specifications of

632HP195506591   ·  2023-01-25 01:20:35   ·   energy

A large number of personnel are not allowed to select goods in the warehouse. Close the warehouse door in time. When the warehouse door is opened, pay attention to whether the air curtain is opened or the door curtain is placed properly. Turn off the lights when leaving the warehouse.Panel types of quick freezing warehouse: color plastic steel plate, salted steel plate, stainless steel plate, embossed aluminum, etc.Veracruz,Do a good job of power failure early warning. The management personnel of the controlled atmosphere storage shall often pay attention to the notice of the local power department. In case of power restriction or line transformation, they shall do a good job in time. For sudden power equipment failure and artificial line, it is recommended to install power failure alarm, receive the alarm in time, and the loss will be reduced to a low level.The lights in the warehouse are not on. Please check whether the switch fails and whether the bulb is damaged. Cut off the power supply when installing the lampshade, and pay attention to the waterproof of the lamp.Awka,Families will also be equipped with some simple refrigeration devices. For refrigeration devices such as cold storage, it is very important to select materials with good thermal insulation. Cold storage is a better material selection, and in the production process of cold storage, there will be no condensation in the cold storage of the plant. Condensation inside the cold storage or inside the insulation layer is harmful. Irreversible damage or deformation occurs in the new external insulation,VeracruzInstallation price of small cold storage, and the external surface temperature of the external wall changes sharply. For example, the insulation and sound insulation effects of polyurethane insulation board are relatively good, which can be used in many industries. As we all know, the cold storage has great requirements for the thermal insulation effect of building materials. If the thermal insulation effect of building materials is not good, the cold storage will consume more energy during operation, and can not guarantee a good refrigeration effect. The performance of polyurethane insulation board meets the construction requirements of cold storage, so a large number of polyurethane insulation boards need to be used in the construction of general cold storage. Next, let's understand the physical properties of polyurethane insulation board.Emergency measures during the use of the medical cold storage project, it may also encounter power failure or power failure. In fact, most medical cold storage projects will be equipped with emergency equipment,VeracruzWhich one do you want for cold storage installation, so that the medical cold storage project can achieve the effect of normal power supply. Once the automatic temperature or humidity monitoring system is abnormal, the cold storage door should be closed in time, So as not to expose more air conditioners, resulting in corresponding problems in the quality of stored products. The medical cold storage project also has a self rescue system in time. If the temperature of the cold storage exceeds the limit, the system cooling system will also be turned on. When the temperature returns to normal,VeracruzConstruction and installation cost of cold storage, a simple analysis is made on the reasons for the slow drop of temperature: the cold capacity loss of quick freezing storehouse is large due to poor thermal insulation or sealing performance; the poor thermal insulation performance is due to insufficient thickness of thermal insulation layer of pipeline and warehouse thermal insulation wall, resulting in poor thermal insulation and thermal insulation effect, It is mainly caused by improper selection of insulation layer thickness in design or poor quality of insulation materials in construction.


VeracruzFruit and vegetable cold storage installation companyCharacteristics and common specifications of



The evaporator surface is too thick or too much dust, and the heat transfer effect decreases: another important reason is that the heat transfer efficiency of evaporator is low, which is mainly caused by excessive frost or excessive dust on the evaporator surface.Air valve leakage and ring leakage will not only affect the rise of exhaust temperature of fresh-keeping warehouse, but also change the interstage pressure. As long as the compression ratio is higher than the normal value, the exhaust temperature will rise.The ground insulation of small medium and large cold storage is different, which is closely related to the purpose, storage products and size of cold storage. Kuhua refrigeration reminds: ground insulation must be done, otherwise the temperature in the cold storage often fluctuates frequently due to poor insulation performance, which affects the quality of stored goods. So, what is the difference between the ground insulation of small, medium and large cold storage? How to do better?Convenient and efficient,When installing polyurethane insulation board, ensure that its surface is smooth and flat without scratch and warpage.The cooking materials and foods refrigerated in the quick-frozen warehouse contain a certain amount of fat, it is necessary to carry out the hygienic disinfection of cold areas regularly.When installing polyurethane insulation board, ensure that its surface is smooth and flat without scratch and warpage.


VeracruzFruit and vegetable cold storage installation companyCharacteristics and common specifications of



Cold storage construction: which one is suitable for you? Which one is suitable for you?Interpretation and observationInstallation of unit electrical box: the unit electrical box shall be installed near the unit; Vertical installation. If the unit is installed on the top of the warehouse, the distance between the box bottom and the top of the warehouse must be & amp; gt; mm; The electrical box can be fixed on the building wall or on the angle steel frame.Scroll refrigeration unit: at present, scroll refrigeration unit is mainly in fully enclosed structure, use a hammer to pad the wood on the polyurethane warehouse board between the two warehouse boards, so as to make the boards closely close to each other. Two sets of connecting pieces shall be wedged between the wall panel and the wall panel, and the two sets of connecting pieces shall be fixed on the upper, so that the post cast concrete can cover the connecting piece. After the gap between the plate and the plate ground is wedged with a connector, it shall be about mm wide. If it does not meet the requirements, remove the plate, trim the plate edge and then reinstall it to make the plate joint meet the requirements. When fixing the adapter, pay attention to fix the two parts of the adapter on the edges of the convex and concave library plates respectively, and fix them with rivets. The spacing of the adapter should be able to tension the two library plates. When wedging the wedge iron, the hammer shall be perpendicular to the wedge iron to prevent damaging the warehouse plate. The ground wedge iron at the upper and lower parts shall be wedged at the same time, and the wedge iron shall be fixed with rivets.Veracruz,When outdoor air enters the cold storage body, it will not only increase the cold consumption of the cold storage, but also bring water into the warehouse. The condensation of water will lead to the building structure, especially the heat insulation structure, being damaged by moisture and freezing. Therefore, a moisture-proof and heat insulation layer should be set to keep the cold storage board building moisture-proof and air-proof performance and good sealing.The cold storage belongs to a kind of refrigeration equipment. Compared with the refrigerator its refrigeration area is large, but they have the same refrigeration principle. So how to maintain the cold storage every day. Today I'll introduce how to do a good job in the daily management and maintenance after the installation of the cold storage.Fault phenomenon: high current or tripping during unit startup, and problems of user air switch; Input voltage is too low; The star angle conversion interval is too short (it should be ~ seconds); Hydraulic cylinder failure (no reset); Intake valve failure (too large opening or stuck); Loose wiring; Host failure; Main motor fault; TR time relay is broken (relay unit).

0 Replies   |  until 2023-01-25 01:20:35 | 24 Views
Log inContent can only be published later