PontarenasRefrigerated vegetables in cold storageThe manufacturer shall pay attention to its maintenance

632HP195506591   ·  2022-06-23 07:48:44   ·   energy

The two sets of connectors between the cold storage shall be wedged tightly, and the two sets of connectors shall be fixed at the upper,PontarenasHow much is the installation cost of small cold storage, outer and lower sides of the cracks in the cold storage respectively. The lower connector shall be as close as possible, so as to facilitate the use of concrete to cover the connector in the future.Commissioning cold storage. After all parts of the cold storage are installed and connected, the cold storage can be started for cold storage commissioning. According to the needs of customers adjust the value of the cold storage, the cooling speed and the operation of the cold storage are normal, and the cold storage can be delivered for use. The cold storage installation unit shall also provide the cold storage user with training on cold storage use and management knowledge, as well as some after-sales training.Pontarenas,The general installation of air-conditioned storage will use air coolers for refrigeration. In this case, the temperature of such a controlled atmosphere reservoir may be too low. It is suggested that the unit can adjust the scale a little larger in the process of temperature setting.During installation, the plates shall be handled with care. Rough operation is strictly prohibited. Burrs shall be removed at the cutting opening to prevent scratching the plate surface and workers.ChomaGeneral quick-frozen warehouses are mostly cooled by refrigeration mechanism with low gasification temperature (ammonia or Freon)During the production of cold storage, the cold storage will produce fixed length, width and thickness according to the needs of various cold storage projects. Generally, cm thick cold storage plates are selected for high and medium temperature cold storage. The requirements for cold storage engineering plates of low-temperature storage and quick-frozen storage will be higher. Professional cold storage installation, installation, construction, fruit fresh-keeping cold storage and medical cold storage ensure the quality, Guarantee service. Guarantee quality. Your satisfaction is our pursuit! Welcome to inquire. In this case, use cm or cm thick library board. When you budget the cold storage project, you can make a reservation according to the specific conditions of your cold storage temperature. If you don't make a reservation for the cold storage plate, you should pay attention to the density of the cold storage plate and the thickness of the steel plate when purchasing the cold storage plate. According to regulations, the foaming density of cold storage is per cubic meterIn order to prevent damage to the cold storage, it is necessary to lay some foam on the floor of the cold storage tank.


PontarenasRefrigerated vegetables in cold storageThe manufacturer shall pay attention to its maintenance



- precautions for floor installation of cold storage: the floor shall be installed flat, and the locking hook between the plates shall be locked to ensure that the warehouse surface is flat without hollow feeling. (note that if this drainage system is installed outdoors in the north, the drainage pipe shall be insulated).Frequently check and acknowledge whether the voltage of the power supply meets the requirements, and the voltage should be V & plusmn; % (phase line). When the fresh-keeping warehouse equipment is not used for a long time, the main power supply of the fresh-keeping warehouse shall be cut off, and it shall be ensured that the fresh-keeping warehouse equipment is not affected by moisture, dust and other substances. The condenser on the refrigeration unit is simply contaminated, and the fresh-keeping warehouse shall be cleaned regularly according to the actual situation. To adhere to outstanding heat transfer.During the production of cold storage, the cold storage will produce fixed length width and thickness according to the needs of various cold storage projects. Generally, cm thick cold storage plates are selected for high and medium temperature cold storage. The requirements for cold storage engineering plates of low-temperature storage and quick-frozen storage will be higher. Professional cold storage installation, installation construction, fruit fresh-keeping cold storage and medical cold storage ensure the quality, Guarantee service. Guarantee quality. Your satisfaction is our pursuit! Welcome to inquire. In this case, use cm or cm thick library board. When you budget the cold storage project, you can make a reservation according to the specific conditions of your cold storage temperature. If you don't make a reservation for the cold storage plate, you should pay attention to the density of the cold storage plate and the thickness of the steel plate when purchasing the cold storage plate. According to regulations, the foaming density of cold storage is per cubic meterRecommendation and consultation,Precautions for purchase and shipment when using the medical cold storage project, the speed must be strictly guaranteed during the purchase and shipment of products. If the temperature of the medical cold storage is about degrees, the opening time must be strictly within minutes. If the temperature of the medical cold storage is left and right degrees, the opening time can not be too high, strictly within minutes.Whether the water pump works normally and whether the moldy switch is effective. In case of abnormality, timely handle the overhaul and maintenance of the refrigeration compressor in the cold storage: generally, the refrigeration oil and drying filter shall be replaced times after the operation of the cold storage equipment. Replacement after half a year. Depending on the circumstances.Indirect cooling is that the air in the warehouse is pumped into the air cooling device by the blower. The air is absorbed by the evaporation pipe circling in the cooling device, and then sent to the warehouse for cooling. The advantages of air cooling are rapid cooling, uniform temperature in the warehouse, and can bring harmful gases such as carbon oxide out of the warehouse during storage.


PontarenasRefrigerated vegetables in cold storageThe manufacturer shall pay attention to its maintenance



During production in the production workshop, the unit weight of Pu warehouse board shall not be less than the unit weight required by the project, not less than & plusmn; kg/m.supply,PontarenasWhich one is good for cold storage installation,No matter whether the food cold storage or quick-frozen storage is in use, it is inevitable that there will be various small faults. Don't be nervous when there are problems. You can find or eliminate problems according to the knowledge taught today.The gap between the cooling fan and the storage plate shall be greater than the thickness of the cooling fan.Stretch perlite: stretch perlite is a kind of granular material with porous layout. The gap in it blocks out the heat. Professional cold storage installation, cold storage installation, cold storage construction, fruit fresh-keeping cold storage, strict testing, quality assurance. Preferential activities are in progress. Welcome to consult. It has a good heat insulation effect. Then, the water vapor in the cold storage is easy to condense, and the water absorption of extensional perlite is particularly strong. If it absorbs a lot of water, its nature will be greatly reduced. Therefore, it is necessary to be careful to select extensional perlite as cold storage.Pontarenas,The spacing of pull rivets at inner and outer corners is mm and mm respectively; After the polystyrene library is installed, the wall panel joints shall be evenly sealed and decorated with silicone sealant.The equipment that needs to be installed in the warehouse and put into the warehouse shall be installed in place or placed in an appropriate position in the warehouse; The wall warehouse board shall be installed from the corner of the warehouse body, and the professional cold warehouse shall be installed. The cold warehouse shall be installed. The cold warehouse shall be constructed. The fruit fresh-keeping cold warehouse and medical cold warehouse shall have high pressure rating, good waterproof performance, fire and high temperature resistance,PontarenasProfessional installation of cold storage, strong overload capacity, corrosion resistance, radiation protection and long service life. The corner shall be temporarily fixed with . color plate angle steel; When installing each wall panel, and apply one layer of foaming material when installing polystyrene wall panel. The blanking shall be uniform and continuous; After the wallboard is installed in place, pull rivets at the lap joint of the internal and external steel plates of the two wallboards for connection and fixation, and the rivet spacing in the warehouse should be mm; When connecting the library plate in the form of eccentric hook connection, the eccentric hook shall be loosened once before installation to ensure reliable locking during installation.Cold storage, low pressure too low lack of refrigerant, excessive air intake, compressor jamming.

0 Replies   |  until 2022-06-23 07:48:44 | 95 Views
Log inContent can only be published later