St. ClaudeDesign cold storage installationIf you don't take good care of it, something will happen

632HP195506591   ·  2022-12-05 00:13:12   ·   energy

The equipment that needs to be installed in the warehouse and put into the warehouse shall be installed in place or placed in an appropriate position in the warehouse; The wall warehouse board shall be installed from the corner of the warehouse body, good waterproof performance, fire and high temperature resistance, strong overload capacity corrosion resistance, radiation protection and long service life. The corner shall be temporarily fixed with . color plate angle steel; When installing each wall panel, evenly apply two layers of foaming material on the joint surface of male and female groove, and apply one layer of foaming material when installing polystyrene wall panel. The blanking shall be uniform and continuous; After the wallboard is installed in place, pull rivets at the lap joint of the internal and external steel plates of the two wallboards for connection and fixation, and the rivet spacing in the warehouse should be mm; When connecting the library plate in the form of eccentric hook connection, the eccentric hook shall be loosened once before installation to ensure reliable locking during installation.At ordinary times, users should check the sealing degree of the gap of the cold storage, and notify the cold storage for maintenance in time if damaged parts are found.St. Claude,Ammonia filling leak test: ammonia filling leak detection can be carried out after system blowdown and pressure leak test. The purpose is to improve the air tightness of the system and lay a good foundation for the work of ammonia filling and thermal insulation materials of the system. After air leakage detection, some obvious leakage points can be found. However, due to the poor air permeability, the leakage points blocked by dirt along the tiny sand holes are not easy to be detected. Therefore, ammonia must be filled. In addition to good permeability, ammonia also has odor and is easy to be found, At the same time, phenolphthalein test paper can be used for leak detection because it is rose red in the presence of ammonia.However, long-term continuous operation will inevitably lead to equipment aging, so reasonable maintenance is particularly important.Betim,Step of cold storage design: define the volume of the cold storage warehouse. The size of the cold storage should be based on the design of a large number of agricultural products to be stored for a long time. This volume is calculated based on the essential volume of stored goods accumulated in the cold storage, plus the row to row corridors, the indoor space between the pile and the wall, the ceiling and the gap of the packaging house. After the volume of the cold storage is determined, the length and height width ratio of the cold storage shall be determined. Necessary auxiliary engineering buildings and equipment shall also be considered in the design of cold storage,St. ClaudeInstallation of small refrigerator, such as working intermediate, packaging and combing room, special tool warehouse loading and unloading platform,St. ClaudeRefrigerated drugs, etc.During the installation of long-span top warehouse plate, if the supporting steel beam has been installed in the warehouse, the top warehouse plate and the supporting steel beam shall be fixed with pull rivets during the installation of each warehouse plate, and each top warehouse plate shall be riveted in two rows; If the lifting point type is adopted, the installation and construction of the lifting layout shall be realized before the installation and construction of the top silo plate, so as to ensure that each lifting point can be installed at the same time during the installation of the top silo plate; The lifting point shall ensure that there are at least two points along the width direction of each warehouse plate.A large number of personnel are not allowed to select goods in the warehouse. Close the warehouse door in time. When the warehouse door is opened, pay attention to whether the air curtain is opened or the door curtain is placed properly. Turn off the lights when leaving the warehouse.


St. ClaudeDesign cold storage installationIf you don



When using the cold storage, try to keep the ground clean and professional cold storage installation,Wires should not be in the open air to avoid long-term sun exposure and wind blowing, wire skin aging, long-term cold storage installation, installation of cold storage, cold storage construction, fruit preservation cold storage, medical cold storage without turnover, so as to avoid price difference, and the price is % higher than the market price! The price of more than one ton is higher! Short circuit, leakage, it is inevitable that there will be various small faults. Don't be nervous when there are problems. You can find or eliminate problems according to the knowledge taught today.Where to sell API,Acid disinfectant can be used for mold removal and disinfection of quick-frozen warehouse.When using the cold storage, try to keep the ground clean and professional cold storage installation,Reasonable space: the power consumption of the cold storage is calculated according to the cold consumption of the cold storage, which usually includes two parts: the cold consumption during cargo cooling and refrigeration; It is the cooling consumption of the refrigeration room itself and operation management.


St. ClaudeDesign cold storage installationIf you don



The drainage at the outlet of the cooling fan the drainage of the volatile cooler and the road drainage of the refrigerated warehouse storing food or drinks shall not be immediately connected with the sewage and wastewater pipeline system software, but indirect drainage shall be adopted. For the flushing (thawing) water drainage of each layer in the double-layer cold storage, an exhaust valve equipment shall be set in front of the main riser for flushing (thawing) water drainage.Quality Assurance, - Installation of the vertical plate of the cold storage: select the angle first according to the site conditions and locate it (i.e. lock the vertical plate and the floor) to extend to both sides at this angle. Only lock the vertical plate and the vertical plate, and locate it when it meets the vertical angle. Put the beautiful plate in a conspicuous place. When installing it on the side of the evaporator, make the drainage pipe in advance, and make U-bend and silica gel outside the storage.Air conditioning monitoring pan geographic air conditioning room monitoring system consists of front-end equipment, client / device app and PC large screen.No matter whether the food cold storage or quick-frozen storage is in use, it is inevitable that there will be various small faults. Don't be nervous when there are problems. You can find or eliminate problems according to the knowledge taught today.St. Claude,Various construction materials,St. ClaudeWhich is a good cold storage design and installation, test report and stage acceptance record, shall be carried out simultaneously with the project construction, carefully, timely, accurately and comprehensively reflect the whole process of production and construction, pay attention to whether the air curtain is opened or the door curtain is placed properly. Turn off the lights when leaving the warehouse.Frequently observe the operation state of the heart compressor of the cold storage equipment and its exhaust temperature. During the season change operation, pay special attention to the operation state of the system and adjust the liquid supply and condensation temperature of the system in time.

0 Replies   |  until 2022-12-05 00:13:12 | 51 Views
Log inContent can only be published later