Sesto San GiovanniSmall household elevatorDedicated service system

938HP166090698   ·  2024-05-06 03:01:40   ·   Machinery and industry equipment

The beam edge distance is too small: The method of shortening the lower platform is to shorten the total length of the escalator, but note that the range of shortening is very limited, generally not exceeding mm. Generally, the platform cannot be shortened because it contains equipment such as cabinets and motors. Change the angle of the escalator from degrees to degreesThe speed limiter tensioning device and the steel belt tensioning device should be equipped with a safety switch.Sesto San Giovanni,Factors to consider when choosing a household elevator: . Safety. Generally, brand elevators must have third-party testing, and elevators that have been inspected by professional organizations are safe, and guaranteed to be used with peace of mind. In addition, when choosing to purchase villa elevators, it is important to understand the safety components and configuration of this elevator. The essential safety equipment in the villa elevator includes a backup power supply and an emergency call outside telephone system to ensure the safety of private users on the elevator.The effective support width of the upper and lower support beams should be greater than the width of the escalator truss and there should be embedded steel plates.Gramsh, the elevator components in operation are inspectedThere is a dedicated fire telephone in the fire elevator car.The door closing button has no self maintenance function. During the designated maintenance period, refueled, dust is removed, and safety devices are debugged. Including non-destructive testing and maintenance of elevator traction steel wire ropes.In the event of a fire, when instructed by the fire center or the dedicated operation button of the first floor firefighter to enter the firefighting state,Sesto San GiovanniFully automatic hydraulic tipping machine hopper, the elevator should immediately stop on the floor without opening the door, return to the first floor station, and automatically open the elevator door if it is in the upward direction.


Sesto San GiovanniSmall household elevatorDedicated service system



Tower style residential buildings above; Residential units and corridors with twelve or more floors; Other Class II public buildings with a building height exceeding meters; High rise buildings with elevators exceeding meters in height; The functional fire elevator has a front room. The area of the independent fire elevator front room is: the front room area of the residential building is greater than square meters; The front room area of public buildings and high-rise factory (warehouse) buildings is greater than square meters. When the front room of the fire elevator is shared with the smoke proof staircase, its area is: the area of the shared front room in residential buildings is greater than square meters, and the area of the shared front room in public buildings and high-rise factory (warehouse) buildings is greater than square meters.Will the elevator quickly fall during a power outage& mdash;& mdash; Some movies and TV dramas often mislead the public into thinking that if the elevator loses its power, it will lose control and engage in falling movements.The basic content of escalator shaft measurement is to measure the lifting height. The same as measuring the height of a straight ladder, strictly speaking, the lifting height of a ladder is the vertical distance between the finished ground at the upper and lower support beams. When using the suspension line method to measure, attention should be paid to whether there is a drop between the positioning point of the line drop and the decoration surface of the lower support beam of the ladder.agent,The shaft for updating the old elevator: The measurement of the shaft for the old elevator is the same as the shaft that has just been constructed. When the old elevator is not yet in use, try to obtain relevant data outside the shaft, such as the size of the machine room, and net size of the door opening. There are two situations when the old elevator is not yet in use: a. When the old elevator can start: in this case, the elevator technician must cooperate in measuring the shaft! And be sure to pay attention to safety! The elevator technician opens the hall door on the first floor and initiates maintenance operations to drive the car above the second floor. The measurement personnel open the floor door on the first floor to measure the pit data, paying attention to recording the pit size and the wall structure of the first floor, such as whether the hall door is centered, whether there are brackets whether there are special structures on the shaft wall, the spacing between ring beams, and the position of embedded parts. Then,Sesto San GiovanniVilla Home Indoor Small Elevator, the measuring personnel and elevator technicians take the elevator to the top floor. After measuring the machine room, the measuring personnel, go up to the car roof and start the elevator at a maintenance speed. When the car roof is slightly lower than the sill of the second floor hall door, the parking lot stops. During this process, the measuring personnel observe and measure the full travel of the shaft from the top floor, mainly the height of the floor, while recording the measurement (safety must be paid attention to, and special attention should be paid to moving parts such as counterweights and wire ropes).For escalators that require intermediate support, it is necessary to determine whether the site has the conditions for adding support, as well as the range of support that can be added, the height and load size of the equipment and support platform, and other parameters.The door closing button has no self maintenance function. During the designated maintenance period, the elevator components in operation are inspected, refueled, dust is removed, and safety devices are debugged. Including non-destructive testing and maintenance of elevator traction steel wire ropes.


Sesto San GiovanniSmall household elevatorDedicated service system



Please note that there should be a space of over mm left on both sides of the escalator,Sesto San GiovanniHousehold elevator for a three story villa, and when arranged in parallel, there is no restriction between the two escalators.A complete range of products,Electrical safety. Faulty elevators have multiple safety devices, but there are also many places where problems can occur. Some people have been caught due to abnormal door opening and closing while others have encountered situations where elevator buttons malfunction and the display screen is black, making it difficult to see the floor clearly. Some have experienced the danger of falling straight several floors. Although there may not have been any personal injury, taking the elevator is not about finding or acting in a movie. The real life is disturbed by the frequent elevator accidents, which make my heart feel uneasyHousehold elevators have gradually become an essential vertical transportation tool for modern single family, duplex, multi story, villa and other residential buildings, practical and convenient, and even a beautiful scenery in the home.During the use of elevators, some elevator users seek temporary workers or unqualified companies for elevator maintenance in order to reduce costs and save funds. Once safety issues arise, even the responsible unit cannot be found. If the maintenance is carried out by elevator manufacturers or qualified professional companies, on the one hand, and on the other hand, if any problems occur, someone is also responsible.Sesto San Giovanni,If the elevator is in a downward direction, immediately close the door and return to the first floor station, and automatically open the elevator door.The front room of the fire elevator is equipped with Class B fireproof doors or fireproof rolling shutters with stopping function.Multiple elevator shafts can be connected and an - # I-beam can be fixed at a certain height between each adjacent elevator shaft, with the same position as the ring beam. The pit must be equipped with an isolation net that is mm above the ground level.


0 Replies   |  until 2024-05-06 03:01:40 | 16 Views
Log inContent can only be published later