not badElevator electric platformThe number of overhauls is on the rise

935HP175192871   ·  2024-04-21 00:36:42   ·   Machinery and industry equipment

Setting requirements: Before starting work every day and changing shifts, the driver of the construction electric elevator should inspect the construction electric elevator according to the requirements of the user manual and specifications, record the inspection results, the driver of the construction electric elevator should inspect the construction electric elevator according to the requirements of the user manual and specifications, and report any problems found to the user unit.not bad,During maintenance or when problems occur, the power supply should be cut off in a timely manner. After lifting, the aluminum alloy electric elevator should be firmly fixed before maintenance can be carried out. It is strictly prohibited to operate with defects to avoid accidents.The spacing between wall brackets and the height of guide rails above the high attachment point should comply with the requirements of the user manual.South Africa,Speed limiter. To prevent the driving speed from exceeding the normal speed. A speedometer should be installed (not required for floors below or including the second floor), which is an individual mechanism that is integrated with a safety clamp; The entrance and exit of the passenger compartment should be equipped with safety doors. Public places family dormitories, andThe angle between the wall bracket and the horizontal plane should comply with the requirements of the user manual.Use floor doors and cage door devices on construction sites where conditions permit.


not badElevator electric platformThe number of overhauls is on the rise



The entrance of each landing platform must be equipped with a landing door, which must open towards the landing platform side, and the door bolt must be set on the side next to the construction electric elevator.Folding arm electric elevators are mostly driven by hydraulic means, and the source of power for the hydraulic system is hydraulic oil. Only when the hydraulic oil quantity is sufficient and the oil quality is high, can the folding arm electric elevator provide greater torque output, thereby improving work efficiency. So, how can we determine whether the newly added hydraulic oil quantity is sufficient? What is the hydraulic oil quantity standard?During normal operation, the horizontal distance between the closed cage door and the closed landing door should not exceed mm. Otherwise, measures should be taken to make it meet the requirements, or side protection devices at the entrance of the landing station that meet the requirements should be equipped. The distance between any opening between the side protection device and the hanging cage or landing door should not exceed mm.Inspection items,Setting requirements: When the distance between the outer edge of the construction electric elevator and the external overhead power line cannot meet the requirements of a small safety distance, the protective measures taken should comply with the specification requirements.The use of a lifting platform as a tool for storing performance blankets soft scenery, etc. In some theaters, there is a soft scenery storage lifting platform located at an appropriate location on the stage for the storage of blankets, soft scenery,not badWalking electric elevator, etc.Steel wire ropes, pulleys, and counterweight steel wire ropes shall comply with the following regulations: the characteristics of steel wire ropes shall comply with the requirements of General Purpose Steel Wire Ropes GB/T; Maintenance, wear, deformation, and corrosion of steel wire ropes


not badElevator electric platformThe number of overhauls is on the rise



Setting requirements: The foundation and foundation of the construction electric elevator should meet the requirements of the user manual. Before installing the construction electric elevator, the foundation should be inspected and accepted according to the requirements of the specifications. Only after passing the inspection can the installation be carried out.Discount,When applying a normal force of N to any position on either side of the door using a rigid mm square or circular flat surface in the locked position of the landing door, the door should be able to withstand and have no deformation; - Deformation not exceeding mm; After the test, it worked normally.Lowering platform vehicle mounted lifting platform, self-propelled lifting platform, diesel engine curved arm self-propelled lifting platform, folding arm lifting platform, cylinder sleeve lifting platform, and specialWhen the foundation is set on the roof or floor structure,not badSelf propelled electric elevator, the bearing capacity of its supporting structure should be checked.not bad,Drivers of construction electric elevators should hold special construction operations and are not allowed to operate without a certificate.Low power consumption: When the hydraulic guide rail lifting platform descends, it is driven by the pressure generated by its own weight, greatly saving energy and reducing consumption.Protective measures should comply with regulatory requirements.


0 Replies   |  until 2024-04-21 00:36:42 | 23 Views
Log inContent can only be published later