DanbicaElfordInspection requirements during installation

935HP175192871   ·  2024-04-10 02:02:36   ·   Machinery and industry equipment

Spiral electric lifting mechanism: With all the functions of a regular lifting platform, the main feature is that the equipment occupies a small foundation pit and has a large stroke. The equipment has a height of only -mm and a travel distance of up to m. It is particularly suitable for buildings with stages built on two or more floors due to space constraints.There is no need to set up a computer room above the shaft like an elevator,DanbicaTuramor, and the top floor height can be installed at least . meters.Danbica,How to determine the sufficient amount of clean oil for the hydraulic station of an electric elevator? Why cannot water be used to flush the hydraulic station of an electric elevator?Speed limiter. To prevent the driving speed from exceeding the normal speed. A speedometer should be installed (not required for floors below or including the second floor), which is an individual mechanism that is integrated with a safety clamp; The entrance and exit of the passenger compartment should be equipped with safety doors. Public places, family dormitories, andPescara,Manual pump: When the system malfunctions, the manual pump can be operated to pump high-pressure oil to raise the car to the nearest floor positionDrainage measures need to be considered around the foundation. (Drain the accumulated water on the foundation).Use floor doors and cage door devices on construction sites where conditions permit.


DanbicaElfordInspection requirements during installation



From the perspective of the safety performance of the machinery itself, those that have undergone national safety certification will not have significant safety issues. The main problem is that after using the electric elevator for a period of time, mechanical components may fall off or be damaged due to various factors. This problem depends on regular inspection and maintenance of the machineryConstruction electric elevators should be equipped with safety devices to prevent the cage from falling. The anti fall safety device should be functional at all times, including installation, disassembly, and before resetting after action. Fall arrest safety gearSetting requirements: Each landing entrance should be equipped with a landing door,DanbicaYaodu, which should cover the opening with its full width, and should not open towards the lifting passage.Customer first,The landing door should meet the requirements of the specifications and achieve standardization.Secondly, for the replacement of hydraulic oil on the lifting platform, it is recommended to replace it every three months. If the frequency of use is not high, it can be replaced once a year. The hydraulic oil must be clean and after changing the hydraulic oil, it must be automatically lifted and lowered to times to ensure that the air in the oil cylinder is completely discharged, and ensure that the lifting platform can be lifted to the rated lifting height.Horizontal lead screw mechanical electricity


DanbicaElfordInspection requirements during installation



Horizontal lead screw mechanical electricityInstallation material list,Small safe operation distance: Circuit voltage (kV) of external power lines<~~~ Small safe operation distance (m) Setting requirements: A small safe distance should be maintained between the outer edge of the construction electric elevator and the edge of the external overhead power line.Setting requirements: Construction electric elevators should be equipped with up travel (limit) switches.Setting requirements: The landing door should be standardized and tooled.Danbica,Setting requirements: Drainage measures should be set up for the foundation of construction electric elevators to ensure smooth drainage.Setting requirements: The quality of the standard section should meet the requirements of the product manual. Before installing the construction electric elevator, all components should be inspected,DanbicaXinji, and standard sections and other components with severe wear and deformation should be replaced.Low level doors should be equipped with interlocking devices that can verify their closed and locked positions. The action of this interlocking device should be at the entrance of the cage. Simple use should not interfere with the operation of the interlocking device. The attached wall bracket should use matching standard products. When the wall bracket cannot meet the requirements of the construction site, it should be designed separately. The design of the wall bracket should meet the requirements of component stiffness, strength, stability, etc.

5 Replies   |  until 2024-04-10 02:02:36 | 63 Views

Development and management of tourist attractions 2024-04-10 11:16:06 support  0 | be opposed to  0

I have been shopping online DanbicaElford for so many years, this is the first time I have taken this seriously. I am very satisfied with the product quality and workmanship.

Loading and unloading container cargo 2024-04-10 10:52:44 support  0 | be opposed to  0

DanbicaElfordHow much is it, can I transfer the goods?

Contract Energy Management Services 2024-04-10 10:01:16 support  0 | be opposed to  0

DanbicaElford The quality is very good, I bought it for the second time, the goods are good, the boss is very good

Engineering fibers for rubber products 2024-04-10 11:08:04 support  0 | be opposed to  0

DanbicaElford The goods have arrived, much better than what you see in the picture!

Manufacture of compounded rubber 2024-04-10 09:37:34 support  0 | be opposed to  0

It’s really a test and waiting. I finally waited for 3 days DanbicaElford to arrive, the opening quality is very good
Log inContent can only be published later