PollyPharmaceutical cold storage manufacturerAnalysis of empty drawing effect of

632HP195506591   ·  2024-04-10 00:32:26   ·   energy

General quick-frozen warehouses are mostly cooled by refrigeration mechanisms, and those with very low gasification temperature are used as coolant to evaporate under low pressure and mechanical conditions, so as to absorb the heat in the warehouse,PollyHow much is it to install a 30 square meter cold storage, so as to achieve the purpose of cooling and reduction.After being stored in the medical cold storage project, ventilating medical products may also emit some odors. Once these odors are stored in a certain quantity they will also have a certain impact on other products. Therefore, we must carry out regular ventilation in the process of daily use, so as to effectively reduce the storage time of products. If the medical cold storage project uses row tube refrigeration, the image of frosting may appear after use for a period of time. If we do not defrost in time,PollyWhich is cheaper to install in cold storage, it will also affect the effect of. Therefore, I hope you must pay attention to defrosting.Polly,Air valve leakage and ring leakage will not only affect the rise of exhaust temperature of fresh-keeping warehouse,PollyInstallation price of cold storage, but also change the interstage pressure. As long as the compression ratio is higher than the normal value, the exhaust temperature will rise.Some cold bridge prevention measures shall be taken at the joints between polyurethane insulation boards.Venustiano-Carranza, good permeability to water vapor, and state of foam pores. It is not connected with each other, and the obturator rate is more than %. It is a dense microporous foam material, which is more dense than the surface of the air, and is not easy to permeate. It is an hydrophobic material. - precautions for floor installation of cold storage: the floor shall be installed flat, the uneven part shall be leveled with materials, and the locking hook between the plates shall be locked to ensure that the warehouse surface is flat without hollow feeling. (note that if this drainage system is installed outdoors in the north, the drainage pipe shall be insulated).Panel types of quick freezing warehouse: color plastic steel plate, salted steel plate, stainless steel plate, embossed aluminum, etc.


PollyPharmaceutical cold storage manufacturerAnalysis of empty drawing effect of



Connect the refrigeration system. Wires and copper pipes shall be used to connect the refrigeration unit, electric control system and other components of the cold storage. The connecting pipes shall be closely connected, and corresponding thermal insulation and protection measures shall be taken.The startup of the air-cooled refrigerator unit shall depend on whether the rotation direction of the fan is correct. If the forward rotation can be started for operation, the reverse rotation indicates that the power wiring is reversed, and the phase sequence must be replaced before startup.The installation of top warehouse plate should be carried out alternately with the installation of wall plate, and the wall plate should leave a gap for withdrawing construction equipment; During the installation of the top warehouse plate, the end steel sheet at the overlap with the wall plate shall be disconnected for mm to prevent the cold bridge from running cold; Two layers of foaming materials shall be evenly and continuously punched on the joint surface between each top warehouse plate. Rivets shall be pulled and fixed at the internal and external lap joints of the steel plate, and the rivet spacing shall be mm; According to the design drawings, if there are supporting beams, columns and supporting steel frames in the warehouse, the setting out and positioning shall be carried out and accurate and clear marks shall be made according to the requirements of the design drawings; Weld or install the support beam column, support steel frame, etc., and the welded junction shall be moisture-proof and treated according to the drawing requirements.The cost is reasonable,Moreover, the butt joint shall be filled with foaming material, and the mm wide color steel plate shall be sealed at the butt joint with pull riveting.Cold storage is mainly used for frozen processing and storage of food


PollyPharmaceutical cold storage manufacturerAnalysis of empty drawing effect of



- precautions for vertical plate of cold storage: vertical plate displayproject,All wiring shall be neat. All switches and keys shall be opened and closed sensitively, reliably and accurately. Special connectors shall be used for wiring, and power protection shall be provided for the box and each power branch.The area of wires in the conduit shall not exceed %.Installation of box and operating device: the design of box shall be reasonable, and the appearance quality shall meet the requirements of beauty and practicality. All buttons, electrical switches, etc. shall be reliable, safe, long-term cold storage installation, cold storage installation, cold storage construction, price advantage and quality guarantee! Easy to identify and operate. The indicator light shall be simple and clear. The device and each switch shall be installed on the upper side outside the warehouse door old brand, which is easy to operate, read data and not easy to be damaged, and shall be reliably fixed. The device box is installed on the door frame plate on the door opening side. The center line of the box overlaps the center line of the door frame plate. The bottom of the box is mm above the ground and is reliably fixed. The lighting lamp and door frame wire switch in the warehouse are installed directly below the device, and the height of the bottom edge of the switch box is about mm.Polly,The type of cold storage to be built in the type of cold storage should be determined according to the type of circulating goods. For example, the cold storage that only circulates vegetables can only build a fresh-keeping cold storage while the cold storage with refrigeration + freezing will be built if there are many types of circulating goods and great difference in storage temperature. As for the size of the cold storage, it should be determined according to the type, quantity, frequency, whether to use shelf stacking and so on. For example, for fruits and vegetables packed in cartons, the storage capacity of -kg per cubic meter can be referred to, and the size of cold storage construction can be estimated in combination with the storage capacity rate of about .-..Panel types of quick freezing warehouse: color plastic steel plate, salted steel plate, stainless steel plate, embossed aluminum, etc.The quick freezing storehouse of vegetables and fruits is not suitable to use exhaust cooling, but use fan to supply air for refrigeration, because the gas in the quick freezing storehouse needs to be circulated and dispersed regularly to avoid carbon oxide poisoning caused by high concentration of carbon oxide in local areas. Therefore, in the quick freezing warehouse, the refrigeration equipment needs to be used together with the air conditioning equipment. The selection of refrigeration equipment is different from that of low-temperature freezer and ordinary quick freezing warehouse.

3 Replies   |  until 2024-04-10 00:32:26 | 41 Views

cutting tool 2024-04-10 09:38:12 support  0 | be opposed to  0

When PollyPharmaceutical cold storage manufacturer offer discount points for activities, contact me when there are discounts

Glyphosate Potassium Salt 2024-04-10 08:43:34 support  0 | be opposed to  0

It's worthy of praise, really good, PollyPharmaceutical cold storage manufacturer I like it very much.

Solid waste environmental treatment engineering design 2024-04-10 09:07:34 support  0 | be opposed to  0

Good seller, PollyPharmaceutical cold storage manufacturer things are very good. Come back in the future. You can buy with confidence.
Log inContent can only be published later